1. All 3M Products
  • 3M™ Attest™ Super Rapid Readout Biological Indicator 1492V for Steam
  • 3M™ Attest™ Super Rapid Readout Biological Indicator 1492V for Steam

    3M ID 70200763566
    • You can get biological indicator results for pre-vacuum steam sterilization cycles in just 24 minutes (about the time it takes to cool a load).
    • Compliant with ANSI/AAMI/ISO 11138‑1:2006/®2010
    • Reduces quarantine times allowing quick and efficient detection of sterilization process failure
    • Self-contained, reducing the risk of false positives due to contamination
     More
    Details

    The 1492V 3M™ Attest™ Super Rapid Readout Biological Indicator is a dual readout biological indicator system specifically designed for super rapid and reliable monitoring of the 132°C 4-minute and 135°C 3-minute Vacuum-Assisted steam sterilization process when used in conjunction with the 3M™ Attest™ Auto‑reader 490.

    The self‑contained design includes a carrier with spores of Geobacillus stearothermophilus and a media ampule containing bacteriological growth medium which meets the requirements for growth promoting ability specified in ANSI/AAMI/ISO 11138‑1:2006/®2010. The spore carrier and media ampoule are contained in a plastic vial topped with a brown cap. A chemical process indicator which changes from pink to light brown or darker upon exposure to steam is located on the top of the cap.The 1492V BI utilizes the α‑glucosidase enzyme system, which is generated naturally within growing cells of Geobacillus stearothermophilus. The α‑glucosidase in its active state is detected by measuring the fluorescence produced by the enzymatic hydrolysis of a non‑fluorescent substrate, 4‑methylumbelliferyl‑α‑D‑glucoside (MUG). The resultant fluorescent by‑product, 4‑methylumbelliferone (MU), is detected in the 490 Auto‑reader. The presence of fluorescence within 1 hour of incubation of the 1492V BI in the 490 Auto‑reader indicates a steam sterilization process failure.The 1492V BI can also indicate the presence of G. stearothermophilus organisms by a visual pH color change reaction. Biochemical activity of the G. stearothermophilus organism produces metabolic by‑products that cause the media to change color from purple to yellow which also indicates a steam sterilization process failure. Use of this indication method is optional and is typically restricted to special studies.

    • You can get biological indicator results for pre-vacuum steam sterilization cycles in just 24 minutes (about the time it takes to cool a load).
    • Compliant with ANSI/AAMI/ISO 11138‑1:2006/®2010
    • Reduces quarantine times allowing quick and efficient detection of sterilization process failure
    • Self-contained, reducing the risk of false positives due to contamination
    • Automatic readout means unambiguous 'YES'/'NO', PASS/FAIL result
    • Puts your instrument turnaround speed into overdrive for improved patient safety

    Suggested Applications

    • For 132°C (270°F) 4 minute and 135°C (275°F) 3 minute Vacuum-Assisted Steam Sterilization (Brown Cap)
    • Used in conjunction with the Attest 490 Auto-Reader for Steam
    Specifications
    Biological Indicator System
    Super Rapid
    Brand
    Attest™
    Cap Color
    Brown
    Model
    1492V
    Overall Height (Imperial)
    2.5 Inch
    Overall Length (Imperial)
    6 Inch
    Product Type
    Biological Indicator
    Product Use
    Load Monitoring
    Sterilization Method
    Steam
    Follow Us