1. All 3M Products
  • 3M™ Cold Shrink Three Conductor Breakout Kits
  • 3M™ Cold Shrink Three Conductor Breakout Kits

    All Models
    Close
    Specifications
    Breakout Boot
    Yes
    Cable Insulation Outside Diameter Range (metric)
    12.7-17.8 mm, 17.8-23.4 mm, 23.4-30.0 mm, 30.0-38.6 mm, 38.8-46.0 mm, 8.4-12.7 mm
    Conductor Size by Voltage
    (15 kV, 100%) 1000 kcmil, (15 kV, 133%) 1000 kcmil, (25/28 kV, 100%) 750 kcmil, (25/28 kV, 133%) 500–750 kcmil, (35 kV, 100%) 500–750 kcmil, (35 kV, 133%) 350–750 kcmil, (15 kV, 100%) 500–750 kcmil, (15 kV, 133%) 500–750 kcmil, (25/28 kV, 100%) 350–500 kcmil, (25/28 kV, 133%) 250–500 kcmil, (35 kV, 100%) 4/0 AWG–500 kcmil, (35 kV, 133%) 1/0 AWG–350 kcmil, (5 kV, 100%) 1–3/0 AWG, (5 kV, 133%) 2–2/0 AWG, (8 kV, 100%) 2–2/0 AWG, (8 kV, 133%) 2–2/0 AWG, (15 kV, 100%) 2–1 AWG, (5 kV, 100%) 4/0 AWG–350 kcmil(5 kV, 133%) 3/0 AWG–350 kcmil(8 kV, 100%) 3/0 AWG–350 kcmil(8 kV, 133%) 3/0 AWG–350 kcmil(15 kV, 100%) 1/0–4/0 AWG(15 kV, 133%) 2–3/0 AWG, (25/28 kV, 100%) 1–1/0 AWG, (5 kV, 100%) 400–500 kcmil, (5 kV, 133%) 400–500 kcmil, (8 kV, 100%) 400–500 kcmil, (8 kV, 133%) 400–500 kcmil, (15 kV, 100%) 250–350 kcmil, (15 kV, 133%) 4/0 AWG–350 kcmil, (25/28 kV, 100%) 2/0 AWG–250 kcmil, (25/28 kV, 133%) 1–4/0 AWG,, (5 kV, 100%) 700–1000 kcmil, (5 kV, 100%) 8–2 AWG, (5 kV, 133%) 6–4 AWG, (8 kV, 100%) 6–4 AWG, (8 kV, 133%) 6–4 AWG, (5 kV, 133%) 700–1000 kcmil, (8 kV, 100%) 700–1000 kcmil, (8 kV, 133%) 700–1000 kcmil
    Conductor Size for 15 kV at 100% Insulation
    1/0–4/0, 1000, 250–350, 2–1, 500–750
    Conductor Size for 15 kV at 133% Insulation
    1000, 2–3/0, 4/0–350, 500–750
    Conductor Size for 25/28 kV at 100% Insulation
    1–1/0, 2/0–250, 350–500, 750
    Conductor Size for 25/28 kV at 133% Insulation
    1–4/0, 250–500, 500–750
    Conductor Size for 35 kV at 100% Insulation
    4/0–500, 500–750
    Conductor Size for 35 kV at 133% Insulation
    1/0–350, 350–750
    Conductor Size for 5 kV at 100% Insulation
    1–3/0, 4/0–350, 400–500, 700–1000, 8–2
    Conductor Size for 5 kV at 133% Insulation
    2–2/0, 3/0–350, 400–500, 6–4, 700–1000
    Conductor Size for 8 kV at 100% Insulation
    2–2/0, 3/0–350, 400–500, 6–4, 700–1000
    Conductor Size for 8 kV at 133% Insulation
    2–2/0, 3/0–350, 400–500, 6–4, 700–1000
    Insulation Rejacketing
    Yes
    Maximum Cable Outside Diameter (metric)
    109.7 mm, 119.4 mm, 140.2 mm, 49.3 mm, 67.8 mm, 78.7 mm
    Number of Conductors
    3
    RoHS 2011/65/EU Compliant
    Undetermined
    RoHS EU Comments
    Contact 3M for information