1. India
  2. All 3M Products
  3. Electrical
  4. Power Cable Connectors
  5. Power Cable Terminations
  6. 3M™ Cold Shrink QT-II Outdoor Termination Kits 5630K Series

3M™ Cold Shrink QT-II Outdoor Termination Kits 5630K Series

Products
  • Track-resistant silicone rubber insulators with built-in Hi-K stress relief
  • Easy installation;insulators are pre-stretched around a spiral-wound, plastic core
  • Void-free, flexible seal without special tools or torches
  • Each kit includes all the materials necessary to make 3 terminations are included (except lugs)
 More
View all details
Product Colour
Product_Color
Products Available
 Product Colour
All Models
Close
Details

3M™ Cold Shrink QT-II Termination Kits provide easy installation for a broad spectrum of indoor and outdoor applications. When the terminator is slipped over a properly prepared cable and the core is removed, the terminator immediately shrinks to the cable's dimensions. The result is a void-free, flexible seal without special tools or torches.

Each 3M™ Cold Shrink QT-II Termination Kit includes: Three 3M™ Hi–K Silicone Rubber Terminations, three 3M™ Mechanical Ground Strap Assemblies, three 3M™ Sealing Mastic Strips, one roll of Scotch® 13 Semi-Conducting Tape, one roll of Scotch® 70 Silicone Rubber Tape, three packs of 3M™ Silicone Grease, one Scotch® Cable Preparation Kit and 1 Instruction Sheet.

  • Track-resistant silicone rubber insulators with built-in Hi-K stress relief
  • Easy installation;insulators are pre-stretched around a spiral-wound, plastic core
  • Void-free, flexible seal without special tools or torches
  • Each kit includes all the materials necessary to make 3 terminations are included (except lugs)
  • Conductor Size Ranges: · 5 kV (100%): 8-2/0 AWG · 5 kV (133%): 8-1/0 AWG · 8 kV (100%): 8-1/0 AWG · 8 kV (133%): 8-1 AWG · 15 kV (100%): 8-4 AWG · 15 kV (133%): 8-6 AWG
  • Withstands voltages of 5 to 15kV and is 110 kV BIL-rated
  • Includes three 4-skirt, 1-piece, cold shrink terminations
  • Meets IEEE Standard 48, Class 1 for outdoor, weather-exposed applications
Specifications
Applications
Cable Termination
BIL
110 kV
Brand
3M™
Breakout Boot
No
Cable Insulation Outside Diameter Range (metric)
16.3-22.9 mm, 21.3-33.8 mm, 27.9-41.9 mm, 33.0-49.5 mm, 8.4-17.5 mm
Conductor Size by Voltage
(5 kV, 100%) 1000-2000 kcmil, (5 kV, 133%) 1000-2000 kcmil, (8 kV, 100%) 1000-2000 kcmil, (8 kV, 133%) 800-1750 kcmil, (15 kV, 100%) 750-1750 kcmil, (15 kV, 133%) 600-1500 kcmil, (5 kV, 100%) 3/0 AWG-300 kcmil, (5 kV, 133%) 2/0 AWG-250 kcmil, (8 kV, 100%): 2/0 AWG-250 kcmil, (8 kV, 133%): 1/0-4/0 AWG, (15 kV, 100%) 2-3/0 AWG, (15 kV, 133%): 4-1/0 AWG, (5 kV, 100%) 350-750 kcmil, (5 kV, 133%) 300-750 kcmil, (8 kV, 100%) 300-750 kcmil, (8 kV, 133%) 250-600 kcmil, (15 kV, 100%) 3/0 AWG-500 kcmil, (15 kV, 133%) 2/0 AWG-350 kcmil, (5 kV, 100%) 750-1500 kcmil, (5 kV, 133%) 750-1250 kcmil, (8 kV, 100%)750-1250 kcmil, (8 kV, 133%) 600-1000 kcmil, (15 kV, 100%) 500-1000 kcmil, (15 kV, 133%) 350-750 kcmil, (5 kV, 100%) 8-2/0 AWG, (5 kV, 133%) 8-1/0 AWG, (8 kV, 100%) 8-1/0 AWG, (8 kV, 133%) 8-1 AWG, (15 kV, 100%) 8-4 AWG, (15 kV, 133%) 8-6 AWG
Conductor Sizes
1 AWG, 1/0 AWG, 1000 kcmil, 1250 kcmil, 1500 kcmil, 1750 kcmil, 2 AWG, 2/0 AWG, 2000 kcmil, 250 kcmil, 3/0 AWG, 300 kcmil, 350 kcmil, 4 AWG, 4/0 AWG, 400 kcmil, 500 kcmil, 6 AWG, 600 kcmil, 700 kcmil, 750 kcmil, 8 AWG, 800 kcmil, 900 kcmil
Indoor/Outdoor
Outdoor Skirted
Insulation Level
100%, 133%
Insulation Rejacketing
No
Lug/Stem Connector Included in Kit
No
Number of Conductors
1
Number of Skirts
4
Product Colour
Grey
Product Series
5630K
RoHS 2011/65/EU Compliant
Undetermined
RoHS EU Comments
Contact 3M for information
Shielding Type
Tape Shield, UniShield®, Wire Shield, Wire-Over-Tape Shield
Voltage